Climate Control System - General Information - Specifications S-MAX/Galaxy 2006.5 (03/2006-)

Lubricants, Fluids, Sealers and Adhesives

Specifications
Refrigerant R134a WSH-M17B19-A
Refrigerant oil WSH-M1C231-B

Refrigerant Capacities (When Charging)

Grams
Air Conditioning 600 ± 15
A/C system with Auxiliary A/C system 850 ± 15

Refrigerant Oil Capacities (When Charging)

Milliliters
Air Conditioning 200
A/C system with Auxiliary A/C system 250

Addition of Refrigerant Oil (When new components are installed)

Milliliters
Air conditioning compressor if the amount of refrigerant oil taken from the faulty compressor is less than 150 ml Drain 50 from new compressor.
Air conditioning compressor if the amount of refrigerant oil taken from the faulty compressor is more than 150 ml Drain 0 from new compressor.
Condenser add 30.
Evaporator add 90.
Accumulator/dehydrator add 90.
Every time refrigerant is evacuated. add 20.
When all new components are installed. add 60.

Clutch air gap

mm
Compressor clutch air gap 0.35 - 0.85

Torque Specifications

Description Nm lb-ft lb-in
Compressor drive plate retaining bolt 13 10

Diagnosis and Testing > < Speed Control