ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2746 > < Initial Inspection and Diagnostic Overview|Page 2744
Page 74
background image

-------------------------------------------------
U21 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE SJB DISCONNECTED

-

Disconnect: SJB C2280b.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the battery ground cable. GO to U30.

No

If the vehicle is equipped with a RETM, GO to U22.

Otherwise, GO to U23.

-------------------------------------------------
U22 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE RETM DISCONNECTED

-

Disconnect: RETM C9029.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the battery ground cable. GO to U31.

No

GO to U23.

-------------------------------------------------
U23 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE HVAC MODULE
DISCONNECTED

-

Disconnect: HVAC Module - EATC C228a or HVAC Module - EMTC C2357a.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

Initial Inspection and Diagnostic Overview|Page 2746 > < Initial Inspection and Diagnostic Overview|Page 2744