isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

HVAC System - Unpleasant Odors When In Use|Page 4594 > < HVAC System - Unpleasant Odors When In Use
Page 2
background image

4.

Drill 5/16"(8 mm) hole in the upper-right corner of the evaporator case. (Figure 2)

CAUTION

Be certain to set the drill bit depth at no more than 1/4" (6 mm). Mark the drill bit 1/4"(6 mm) or less from its tip as a guide. Extending the drill bit
deeper into the case after the hole has been drilled will risk puncturing the evaporator core.

5.

With the blower fan on medium to high speed and using the outside air setting, dispense the deodorizer material J43681-A (w/applicator nozzle)
with the following:

^

Place the tip of the nozzle into the 5/16"(8 mm) drilled hole of A/C evaporator core casing. (Figure 3)

^

Using no more than 30 PSI shop air, set nozzle fluid flow adjustment to full open position (full counterclockwise position), and flood the A/C
evaporator core by discharging 4 fluid ounces of treatment chemical into the casing.

NOTE

2 fluid ounces are required to prime the application tubing and nozzle. The 1/2 gallon container label is graduated in 4 ounce increments.

6.

Plug the 5/16" (8 mm) hole with a 5/16" (8 mm) plug supplied with each treatment kit.

7.

Run the ventilation system 5-10 minutes with the fan on high and windows open.

8.

Reinstall the glove box and any panels, previously removed during Step 2.

* Reinstall the A/C fuse, if previously removed.

The application should last 3-4 months under normal use. Repeat the above service procedure, should odors return after such time.

NOTE

As a preventive measure, service personnel may also suggest to the customer to run the fan blower at mid to high speed with the A/C off and using
the outside air setting to dry the evaporator for the last few minutes before turning off the vehicle.

PARTS INFORMATION

KENT-MOORE Part Number

Description

Quantity

J43681-A

HVAC SYSTEM

1 Kit*

Cleaner-Freshner-Protectant
with application nozzle

J43681-5

Replacement Chemical

(Refill)

(2-1/2 gallon containers)

* A sufficient quantity of 5/16"(6 mm) plug is included with each treatment kit.

NOTE:This product will be available for purchase beginning mid-April 1999.

GREEN ISLAND INC. WARRANTY INFORMATION

HVAC System - Unpleasant Odors When In Use|Page 4594 > < HVAC System - Unpleasant Odors When In Use