isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 4664 > < Leak Check - Repair of Refrigerant Leaks|Page 4662
Page 9
background image

Remove or Disconnect

1. Negative battery cable.
2. Recover refrigerant from the system.
3. Evaporator and accumulator hose from evaporator.
4. O-ring seal.
5. Evaporator and accumulator hose from accumulator.
6. O-ring seal.

-

Cap or plug all open connections.

Install or Connect

1. New O-ring seal.

-

Coat O-ring seal with 525 viscosity refrigerant oil.

2. Evaporator and accumulator hose to accumulator.

Tighten
-

Hose to 41 N.m (30 lb ft).

3. New O-ring seal.

-

Coat O-ring seal with 525 viscosity refrigerant oil.

4. Evaporator and accumulator hose to evaporator.

Tighten
-

Hose to 41 N.m (30 lb ft).

5. Negative battery cable.
6. Refrigerant to the system.

-

Check the system for leaks.

Compressor Sealing Washers

IMPORTANT:  Use the correct washers. There should be a space of 1.2 mm (0.047 in) between the suction/discharge hose block and the compressor
rear head.

1. Clean all of the sealing surfaces with a lint-free rag in order to prevent dirt or foreign material from getting into the following sealing surface

components:
-

The washers

-

The hose block 

-

The compressor ports

2. Install the sealing washer onto the pilots of the suction/discharge fitting.

Ensure that the washers are seated against the surface of the blockfitting.