isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|HD6/HT6|Page 4709 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 4706
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair
HD6/HT6

Remove or Disconnect

1. Recover the refrigerant.
2. Disconnect the electrical connector from the switch in the rear bead of compressor.
3. Remove the switch retaining ring using J 5403 internal snap ring pliers.
4. Remove the switch from the compressor.
5. Remove old O-ring seal from the switch cavity using J 95534-01 O-ring removal tool.

If existing control switch is reinstalled in the compressor, a new O-ring seal must be used and preferably a new retainer ring should also be used. A