isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Non-Turbo|Page 2611 > < Non-Turbo
Page 1
background image

Blower Motor: Description and Operation
RS Models

With the ignition switch in START and the inhibitor switch in PARK or NEUTRAL (automatic transaxle), or with the clutch pedal depressed (manual
transaxle), voltage is applied to the restart relay, and the relay energizes.

When the ignition switch is turned to ON, the relay de-energizes and voltage is applied from the alternator to the heater relay through the normally closed
contacts of the restart relay. The relay energizes allowing voltage to be applied from the main fuse to the blower motor through fuse 1.
The fan switch sends a blower speed request signal to the temperature lever and fan control unit. The temperature lever and fan control unit sends a
blower control signal to the power transistor. The power transistor supplies a current path to ground to the blower motor. If the temperature level and fan
control unit receives a maximum blower motor speed request, it grounds the max hi relay. The relay contacts close, bypassing the power transistor, and
supplies ground directly to the blower motor. The blower motor then runs at full speed.

Non-Turbo|Page 2611 > < Non-Turbo