isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Power Steering Pressure Switch > < Removal Procedure|Page 2956
Page 1
background image

Oxygen Sensor: Service and Repair
Installation Procedure

IMPORTANT:

-

A special anti-seize compound, P/N 5613695, is used on the HO2S threads. This compound consists of glass beads suspended in a liquid graphite
solution. The graphite burns away with engine heat, but the glass beads will remain, making the sensor easier to remove.

-

New or service sensors will already have the compound applied to the threads. If a sensor is removed and is to be reinstalled for any reason, the
threads must have anti-seize compound applied.

1. Apply anti-seize compound or the equivalent to the threads of the oxygen sensor, if necessary.
2. Install the oxygen sensor on the exhaust pipe in its original position.

Tighten: Tighten the oxygen sensor to 55 N.m (40 lb in.). 

3. Connect the pigtail to the wiring harness.
4. Connect the negative battery cable.

Power Steering Pressure Switch > < Removal Procedure|Page 2956