Measure runout of armature core and commutator with a dial gauge. Repair or replace, if it exceeds the limit.

Armature
Standard: 0.05 mm (0.002 in) Max.
Limit: 0.10 mm (0.004 in)

Commutator
Standard: 0.05 mm (0.002 in) Max.
Limit: 0.10 mm (0.004 in)

Polish the commutator surface with sandpaper #500 to #600 if it is rough.

Measure the depth of insulator in commutator. Repair, if it is below the limit.

Standard: 0.05 mm to 0.8 mm (0.02 in to 0.03 in)
Limit: 0.2 mm (0.008 in)