isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 4750 > < Leak Check - Repair of Refrigerant Leaks|Page 4748
Page 4
background image

5. Place the refrigerant container (3) up right on a weight scale (4).

Note the total weight before charging the refrigerant.
a. Open the refrigerant container valve.
b. Open the low side vale on the manifold gauge set. Refer to the manufacturer's instructions for a weight scale charging station.

6. Perform a system leak test:

-

Charge the system with approximately 200 g (0.44 lbs) of HFC-134a.

-

Make sure the high pressure valve of the manifold gauge is closed.

-

Check to ensure that the degree of pressure does not change.

-

Check for refrigerant leaks by using a HFC-134a leak detector.

Leak Check - Repair of Refrigerant Leaks|Page 4750 > < Leak Check - Repair of Refrigerant Leaks|Page 4748