isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Refrigerant Oil > < Leak Check - Repair of Refrigerant Leaks|Page 4749
Page 5
background image

-

If a leak occurs, recover the refrigerant. Repair the leak and start all over again from the first step of evacuation.

7. If no leaks are found, continue charging refrigerant to the air conditioning system.

-

Charge the refrigerant until the scale reading decreases by the amount of the charge specified.
Specified amount: 650 g (1.43 lbs) 

-

If charging the system becomes difficult:
1. Run the engine at idle and close all the vehicle doors.
2. Turn A/C switch "ON".
3. Set the fan switch to its highest position.
4. Set the air source selector lever to "CIRC".
5. Slowly open the low side valve on the manifold gauge set.

WARNING:  Be absolutely sure not to open the high pressure valve of the manifold gauge. Should the high pressure valve be
opened, the high pressure refrigerant would flow backward, and this may cause the refrigerant container to burst.
 

8. When finished with the refrigerant charging, close the low pressure valve of the manifold gauge and container valve.
9. Check for refrigerant leaks.

Refrigerant Oil > < Leak Check - Repair of Refrigerant Leaks|Page 4749