isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Warning Lamp Does Not Come "ON" Steady|Page 4902 > < Warning Lamp Does Not Come "ON" Steady|Page 4900
Page 3
background image

Part 2 Of 2

Chart Test Description:

Number(s) below refer to step number(s) on the diagnostic chart:

1. This test decides whether power is available to SDM warning lamp power feed circuit.
2. This test determines whether the voltage is present in the warning lamp circuit.
3. This test determines it the malfunction is in the instrument cluster.
4. This test checks for open in the warning lamp circuitry.
5. This test isolates the IB04-GRN circuit and checks for a short in the IB04-GRN circuit to B+.
8. This test checks for a short from the SDM warning lamp power feed circuit to ground.
9. This test determines whether the short to ground is due to a short in the wiring.

Warning Lamp Does Not Come "ON" Steady|Page 4902 > < Warning Lamp Does Not Come "ON" Steady|Page 4900