4. Refit the air intake ducting to the generator. The upper section is retained by two screws to the sump body assembly and the lower (horizontal)

section is retained by one screw.

5. Lower the vehicle on the ramp.
6. Fully tighten the generator upper mounting bolt, to 18-24 Nm.

7. Refit the drive belt to the generator.

1. Pass the drive belt around the idler pulley.
2. Using spanner (Churchill JD-230 or Snap On XDHM 1415) on the centre bolt of the belt tensioner idler pulley, rotate the adjuster against

spring tension.

3. Whilst holding the tensioner against spring tension, pass the drive belt over the generator pulley and check that it is correctly located on the

other pulleys. Release the tensioner slowly and remove the spanner. Check the alignment of the belt.

8. Refit the fan and motor assembly.
9. Refit the air cleaner assembly.

10. Reconnect the battery ground cable and fit the battery cover.
11. Reset the radio information and the clock.