Service repair no - 82.30.20/01
WARNING: The air conditioning system is charged with a high pressure, potentially toxic refrigerant. Repairs or servicing must only be carried out by an operator familiar with both the vehicle system and the charging and testing equipment.
All operations must be carried out in a well-ventilated area away from open flame and safe use in the air conditioning system. Recycling heat sources. should always be carried out with equipment Always wear safety goggles and gloves when which is design certified by Underwriter opening refrigerant connections. Laboratory Inc. for compliance with SAE-J1991. Other equipment may not recycle refrigerant to WARNING: Wear eye and hand safety the required level of purity. protection. Open connections slowly in case liquid or pressure is present. Allow to A R134a Refrigerant Recovery Recycling bleed off slowly. Recharging Station must not be used with any other type of refrigerant. CAUTION: Overcharging air conditioning system will cause excessive head Refrigerant R134a from domestic and commercial pressure. sources must not be used in motor vehicle air conditioning systems.
An air conditioning portable Refrigerant Recovery Recycling Recharging Station for use with R134a Evacuation and recharging refrigerant incorporates all the features necessary to recover refrigerant R134a from the air conditioning system, to filter and remove moisture, to evacuate and recharge with the reclaimed refrigerant. The unit can also be used for performance testing and air conditioning system analysis.
The operator must adhere to the equipment manufacturers’ instructions.
and recharging the system.
- Connect a Refrigerant Station to the high and low pressure servicing connections.
- Operate the refrigerant recovery system according to the manufacturer’s instructions.
- Measure the amount of oil discharged from the system. Add an equal amount of new refrigerant oil to compressor before evacuation sequence.
- WARNING: Refrigerant must always be
- recycled before reuse, to ensure that the
- purity of the refrigerant is high enough for
- Add refrigerant oil to compressor if necessary.
- Renew the receiver/drier.
- CAUTION: When a major repair has been
- carried out, a leak test should be carried
- out using inert gas.
- Connect a Refrigerant Station to the high and low pressure servicing connections.
- CAUTION: Whenever the refrigerant
- system is opened, the receiver/drier must
- be renewed immediately before evacuating