01 Circuit02 Introduction03 Multiport fuel injection (MFI-V8)04 Multiport fuel injection (MFI-T16)05 300Tdi06 300Tdi glow plug control07 Starting and charging08 Cruise control09 Ignition and shift interlock10 Anti-lock brake system11 Data link connector12 Instruments13 Warnings and indicators14 Horns15 Radio (EXCEPT Japan)16 Radio (Japan)17 Front wipe/wash18 Rear wipe/wash19 Heated rear screen and mirror demisters20 Electrochromic rear view mirror21 Multi-function unit (MFU)22 Headlamps (EXCEPT Japan)23 Headlamps (Japan)24 Headlamp levelling25 Side lamps26 Stop lamps27 Direction indicator lamps28 Reversing lamps29 Fog guard lamps30 Interior lamps31 Cigar lighter/clock32 Blower controls33 Compressor controls34 Cooling fans35 Power windows36 Sunroof37 Central locking (EXCEPT Japan)38 Central locking (Japan)39 Power seats40 Power mirrors41 Trailer auxiliary socket42 Theft alarm system43 Power distribution44 Fuse details45 Ground distribution46 Component location table47 Component location views48 Connector views49 Harness routing
Land Rover Discovery Electrical Troubleshooting Manual (1996)34 · Cooling fans
34 · Engine

Cooling fans – circuit operation

Make
Land Rover
Model
Discovery Electrical Troubleshooting Manual
Year
1996
Section
Circuit operation › Cooling fans – circuit operation
Cooling fansCooling fans – circuit operation

COOLING FANS – CIRCUIT OPERATION

Cooling Fan and Condenser Fan Operation (MFI-T16)

The Cooling Fan 1 (M141) or Cooling Fans (M141, M142) and Condenser Fan Motors (M113, M121) on vehicles equipped with MFI-T16 engines operate when any of the following conditions occur: 1. The A/C system is operating. 2. The Engine Control Module (ECM) determines that Cooling Fan and/or Condenser Fan Motor operation is required.

Cooling Fan Operation without A/C (MFI-T16)

With the Ignition Switch (X134) in position II, battery voltage is applied to the Cooling Fan Relay (K190) from fuse F3 of the Satellite Fuse Box 1 (P127). When Cooling Fan Operation is required, the Engine Control Module (ECM) (Z132) grounds terminal 85 of the Cooling Fan Relay (K190). The relay energises, applying battery voltage from fuse F3 of the Engine Compartment Fuse Box (P125) to the Cooling Fan Motor 1 (M141). When Cooling Fan Operation is no longer required, the ECM removes the ground supply to the Cooling Fan Relay (K190). The Relay de-energises, removing the voltage supply to the Cooling Fan Motor 1 (M141).

Cooling Fan and Condenser Fan Operation with A/C (MFI-T16)

With the Ignition Switch (X134) in position II, battery voltage is applied to the Ignition Load Relay (K127). The relay is energised, applying battery voltage to the Condenser Fan Relay (K109). When Cooling Fan and Condenser Fan operation is required, the Engine Control Module (ECM) (Z132) grounds terminal 85 of the Condenser Fan Relay (K109). The relay energises, applying battery voltage from fuse F3 of the Engine Compartment Fuse Box (P125) to the Cooling Fan Motors (M141, 142) and the Condenser Fan Motors (M113, M121). When Cooling Fan and Condenser Fan operation is no longer required, the ECM removes the ground supply to the Condenser Fan Relay (K109). The relay de-energises, removing the voltage supply to the Cooling Fans (M141, M142) and the Condenser Fan Motors (M113, M121).