Range Rover (LM) V8-4.4L (2009)
4. Install the driver side closing trim panel.
-
Connect the electrical connectors.
-
Attach the vehicle diagnostic socket.
5. Secure the driver side closing trim panel.
-
Install the screws.
-
Install the clip.
6. Install the driver side floor console extension.
-
Secure the clips.
-
Install the screw.
7. Install the lower glove compartment.
8. Disconnect the battery ground cable.
Driver Side Temperature Blend Door Actuator
Driver Side Temperature Blend Door Actuator
Removal
1. Remove the instrument panel driver side reinforcement.
2. Remove the driver side footwell duct.
-
Remove the 2 Torx screws.
3. Remove the temperature blend door actuator.
-
Disconnect the electrical connector.
-
Remove the 2 screws.
Installation
1. Install the temperature blend door actuator.
-
Tighten the screws.
-
Connect the electrical connector.
2. Install the driver side footwell duct.
-
Tighten the screws.
3. Install the instrument panel driver side reinforcement.
Footwell Vent/Duct Blend Door Actuator
Footwell Vent/Duct Blend Door Actuator
Removal
WARNING:
-
Persons working on the supplemental restraint system (SRS) must be fully trained and have been issued with the safety guidelines.
-
Allow a period of 10 minutes to elapse after disconnecting the battery before undertaking any work on the SRS.
-
The SRS electrical connectors are unique. DO NOT force, or attempt to connect electrical connectors to the wrong sockets.