Page 7
background image

1. INSTALL COOLER CONDENSER ASSEMBLY

a. Install the condenser with the 2 bolts on the bottom side of the condenser.

Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)

b. Install the inverter cooling pipe with the 2 bolts.

Torque: 13 N.m (133 kgf.cm, 10 in.lbf)

HINT:  If the condenser is replaced with a new one, add compressor oil to the new condenser.

Capacity: 40 cc (1.4 fl. oz.)
Compressor oil: ND-OIL 11 or equivalent