a. Remove the 2 bolts (A).
CAUTION: Wear insulating gloves.
NOTE: Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.
b. While loosening bolt B, disconnect the motor cable.
CAUTION: Wear insulating gloves.
NOTE:
-
Removing bolts A and B may cause the cable and the inverter with converter to break.
-
Insulate the removed terminals with insulating tape.
-
Cover the hole where the cable was connected with tape or equivalent (nonresidue type) to prevent entry of foreign matter.
c. Remove the 2 nuts and disconnect the inverter motor cable bracket.
24. SEPARATE AIR CONDITIONING HARNESS ASSEMBLY
a. Disconnect the air conditioning harness assembly.
CAUTION: Wear insulating gloves.
NOTE: Insulate the removed terminals with insulating tape.
25. SEPARATE FRAME WIRE
a. Remove the bolt and disconnect the frame wire.