CAUTION: Wear insulating gloves.
NOTE: Insulate the removed terminals with insulating tape.
26. REMOVE NO. 6 INVERTER BRACKET
a. Remove the 2 bolts and No. 6 inverter bracket.
27. REMOVE INVERTER WITH CONVERTER ASSEMBLY
a. Raise the lock lever and disconnect the inverter with converter connector.
NOTE: Cover the hole where the connector was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
b. Disconnect the wire harness clamp.
c. Remove the 2 clips, and disconnect the No. 8 inverter cooling hose and No. 13 inverter cooling hose.