GS 450h V6-3.5L (2GR-FSE) Hybrid (2007)
a. Install the high voltage fuse with the 2 bolts.
Torque: 4.5 N.m (46 kgf.cm, 40 in.lbf)
NOTE: Be sure to use a torque wrench to tighten the bolts.
2. INSTALL HV RELAY ASSEMBLY
a. Install the HV relay assembly with the 3 nuts.
Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)
CAUTION: Wear insulated gloves.
b. Connect the 7 connectors and clamp to the HV relay assembly.
CAUTION: Wear insulated gloves.
NOTE:
-
Connect the wire wrapped with red tape to the terminal indicated by the "+" mark of the HV relay and the wire not wrapped with red tape
to the terminal indicated by the "-" mark of the HV battery.
-
Make sure that the connectors are engaged securely.