IS 250C V6-2.5L (4GR-FSE) (2011)
NOTICE:
*
Insert the hexagon wrench all the way in and turn it with both hands.
*
Do not apply excessive force after the drive gear stops turning.
HINT
The locks will release when the wrench is turned approximately 360 degrees.
(m)Using a 5 mm hexagon wrench, turn the sliding roof drive gear sub-assembly clockwise to close the lock while measuring the roof lock stroke
(C). C (Roof lock stroke) = A - B
Standard:
1.5 mm (0.059 in.)
HINT
*
If the roof lock stroke (C) is not within the specified range, adjust it by turning the adjustment screw of the roof panel strength
sub-assembly. Loosen the lock screw before turning the adjustment screw.
*
When tightening the adjustment screw of the roof panel strength sub-assembly, the distance (A) between the front header and the
front slide roof panel sub-assembly will become larger, and when loosening it, the distance (A) will become smaller.
*
After the adjustment, tighten the lock screw.
(n) Check the metal top movement.
(1) Apply approximately 200 N (20 kgf, 45 f) of force to part A in the direction shown in the illustration, and measure the amount of roof
panel movement at location B.
Standard:
Less than 1.0 mm (0.039 in.)