lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Brakes - Squawk Noise From The Brake Actuator|Page 6931 > < Brakes - Squawk Noise From The Brake Actuator
Page 2
background image

Required Tools & Equipment

Repair Procedure Overview

The brake bleed procedure consists of 5 main sections:

^

Section 1: Zero Down Accumulator Pressure (Zero Down)

This procedure is used to release the pressure from the accumulator prior to bleeding the brakes (or replacing the brake actuator). Techstream is used
for this procedure.

^

Section 2: Disable Electronic Controlled Brakes (ECB Invalid)

This procedure using Techstream disables the ECB system temporarily to allow the front brakes to be bled manually. Using Techstream to disable
brake control causes the master cylinder cut solenoid to turn OFF and the line from the master cylinder to front brake calipers to open allowing
manual bleeding of the front brakes.

^

Section 3: Front Brake Bleed - Manual Process

This is a two-man process in which one technician pumps and holds the brake pedal while another technician opens the right front bleeder screw to
remove air from the system. The same procedure is repeated for the left front.

^

Section 4: Rear Brake Bleed

^

Right Rear Brake Line Air Bleed

During this procedure Techstream opens the solenoid for the right rear brake line and then the accumulator pump runs during this process to push
fluid and air out of the right rear caliper bleeder valve. During this process the brake pedal is NOT applied - the accumulator pump will
automatically pump fluid out of the right rear caliper bleeder valve. This process bleeds the red brake line (suction line from the accumulator to
the actuator) and passes air out through the right rear caliper bleeder.

^

Left Rear Brake Line Air Bleed

Brakes - Squawk Noise From The Brake Actuator|Page 6931 > < Brakes - Squawk Noise From The Brake Actuator