lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Components|Page 4057 > < Components|Page 4055
Page 2
background image

(a) Install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.

Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)

6. INSTALL NO. 1 INVERTER COOLING HOSE ASSEMBLY

(a) Install the No. 1 inverter cooling hose assembly and No. 1 inverter cooling inlet hose assembly to the inverter with converter assembly with the

2 clips and clamp.
-

Do not deform, bend or scratch the pipes of the inverter with converter assembly. The pipes are made of aluminum and must remain
undamaged to maintain proper seal with the rubber hoses.

-

The inverter hose is connected to the cooling system built into the inverter. Do not apply excessive force to the inverter hose, or the
inverter cooling system may be damaged.

(b) Connect the hose clamp.

7. INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION: Wear insulating gloves.

(a) Install the inverter with converter assembly with the bolt, 3 nuts and inverter bracket.

Torque: 25 Nm (255 kgf-cm, 18 ft-lbf)

-

Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly. When
installing the inverter with converter assembly, do not damage the parts around it.

-

To prevent damage, do not hold the inverter with converter assembly by the connectors.

-

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

Components|Page 4057 > < Components|Page 4055