B3000 SE Regular Cab 4WD V6-3.0L OHV (1998)
13. Remove the three bolts and the three stud bolts.
14. Disconnect the crankcase ventilation hose.
15. Remove the upper intake manifold.
16. Remove the upper intake manifold gasket.
17. Install in reverse order of removal.
NOTE: Clean all the sealing surfaces. Position a new upper intake manifold gasket.
Upper Intake Torque Sequence
CAUTION: Install the three bolts and the three stud bolts.
-
Torque the bolts in the sequence shown in two steps.