CAUTION
ELECTRICAL TROUBLESHOOTING TOOLS
Test Light
The test light, as shown in the figure, uses a 12V bulb. The two lead wires should be connected to probes. The test light is used for simple voltage checks and for checking for short circuits.
Caution
- When checking a control unit, never use a bulb over 3.4W.
Jumper Wire
The jumper wire is used for testing by shorting across switch terminals and ground connections.
Caution
- Do not connect a jumper wire from the power source line to a body ground; this may cause burning or other damage to harnesses or electronic components.
Voltmeter
The DC voltmeter is used to measure circuit voltage. A voltmeter with a range of 15V or more is used by connecting the positive (+) probe (red lead wire) to the point where voltage is to be measured and the negative (-) probe (black lead wire) to a body ground.
Diagnosis Connector
Insert the probe into the service hole when connecting a jumper wire to the diagnosis connector.
Caution
- Do not insert the jumper wire probe into the diagnosis connector terminal, which may damage the terminal.
Ohmmeter
The ohmmeter is used to measure the resistance between two points in a circuit, and to check for continuity and short circuits.
Caution
- Do not attempt to connect the ohmmeter to any circuit to which voltage is applied; this may burn or otherwise damage the ohmmeter.