Evacuation
- Make
- Mazda
- Model
- MX-5 (NA) Factory Workshop Manual
- Year
- 1990–1992
- Section
- Evacuation and Charging › Evacuation
Heater and air conditioner systemsEvacuation
VACUUM PUMP
Evacuation
Whenever the refrigeration system has been exposed to the atmosphere, it must be purged of moisture and air.
- Connect the manifold gauge set. (Refer to page U–28.)
- Connect the center hose of the gauge set to the vacuum pump inlet.
- Start the vacuum pump and open both manual valves.
- When the low-pressure gauge shows approximately 700 mmHg (27.6 inHg), close both manual valves and stop the vacuum pump.
- Verify that the pressure remains the same for 5 minutes or more. If the pressure changes, check the system for leaks, and repair as necessary.
- If no leak is found, start the vacuum pump once again and open both manual valves to obtain 760 mmHg (29.9 inHg).
- After the low-pressure gauge shows lower than 760 mmHg (29.9 inHg), continue evacuating for 20 minutes.
- Close both manual valves and stop the vacuum pump.
- Disconnect the hose from the vacuum pump.
R-12
Charging
- Close the high- and low-pressure manual valves fully after the system is evacuated.
- Install the refrigerant container service valve.
- Open the low-pressure manual valve to charge the system with refrigerant gas.
Note
- When charging of the system becomes slow, run the engine at fast idle and operate the air conditioner.
Caution
- Be sure to keep the container in the upright position to prevent liquid refrigerant from being charged into the system through the suction side, possibly damaging the compressor.
- Never open the high-pressure manual valve while charging the system with the A/C ON. Doing so may cause the refrigerant can to explode.
Parts & tools for this job For 1990 Mazda MX-5
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Mazda MX-5 1990 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.