RX7 2RTR- 1308cc 1.3L FI (1987)
1.
The protrusion of mixing plate is aligned with the groove of intermediate housing.
2.
Two (2) O-rings are fitted in the correct position of the primary air bleed socket. The lower Oring is likely to fall off.
NOTE:
The O-rings are installed onto the air bleed socket prior to shipping, however the lower O-ring has a tendency to fall off during handling. For this reason
we stress that the 2 O-rings be installed in the correct position on the primary air bleed socket prior to installation.