Tribute 4WD L4-2.5L Hybrid (2009)
Intake Air Duct: Service and Repair
Air Cleaner Outlet Pipe Removal/Installation
-
AIR CLEANER OUTLET PIPE REMOVAL/INSTALLATION - HYBRID
CAUTION:Do not disconnect the Air Cleaner (ACL) outlet pipe from the ACL cover. This is to protect the integrity of the hydrocarbon trap.
1. Disconnect the crankcase vent tube from the Air Cleaner (ACL) outlet pipe.
2. Disconnect the mass air flow (MAF) sensor electrical connector.
3. Release the 2 ACL cover clamps.
4. Loosen the ACL outlet pipe-to-Throttle Body (TB) clamp and remove the ACL outlet pipe and ACL cover assembly.
-
To install, tighten to 4 Nm {0.4 kgf-m, 35 in-lbf}.
5. To install, reverse the removal procedure.
NOTE:The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.