mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Thermostat Housing, Engine Cooling > < Thermostat, Engine Cooling|Specifications|Page 4002
Page 2
background image

5. Remove the O-ring seal and water thermostat from the water thermostat housing. Inspect O-ring for damage and replace if necessary.
6. If required, remove water thermostat housing retaining bolts, water thermostat housing and O-ring from lower radiator hose tube. Inspect O-ring

for damage and replace if necessary.

INSTALLATION 

1. Install the water thermostat, O-ring, water thermostat housing (if removed) as shown.
2. Install and alternately tighten the retaining bolts. Tighten bolts to 8-12 Nm (71-106 inch lbs.).
3. Connect the lower radiator hose to the water inlet connection.
4. Lower vehicle.
5. Fill the cooling system with Premium Cooling System Fluid E2FZ-19549-AA or-B in Oregon, F5FZ-19549-CC, in Canada, CXC-8-B, Recycled

Coolant, or equivalent that meets Ford specification ESE-M97B44-A in a 50/50 mixture with water.

6. Start the engine and check all hoses and connections for leaks. Allow the engine to warm up so that the water thermostat opens.
7. Stop the engine. Top off degas bottle as required to maintain minimum cold fill level.

Thermostat Housing, Engine Cooling > < Thermostat, Engine Cooling|Specifications|Page 4002