01 Introduction02 General information03 General data, torque settings and capacities04 Maintenance05 Engine (K Series)06 Engine management (MEMS 3), fuel and emission systems07 Cooling system08 Manifolds and exhaust system09 Clutch10 Manual gearbox11 Automatic gearbox (Stepspeed Em-CVT)12 Drive shafts13 Steering14 Front suspension15 Rear suspension16 Brakes17 Restraint systems (SRS)18 Body19 Heating and ventilation20 Air conditioning21 Wipers and washers22 Electrical23 Instruments
MG TF Factory Workshop Manual (2002-2005)20 · Air conditioning
20 · Heating & A/C

Air conditioning (Performance Guide-lines): Adjustments

Make
MG
Model
TF Factory Workshop Manual
Year
2002–2005
Section
Adjustments › Performance Guide-lines
Air conditioningPerformance Guide-lines

Performance Guide-lines

Carry out this test with bonnet, doors or windows open; air conditioning switched on, temperature control set to cold, face vent mode and blower at maximum speed. Set the air supply control to supply fresh air.

  1. Close low pressure valve on Refrigerant Station.
  2. Close high pressure valve on Refrigerant Station.
  3. Connect Refrigerant Station to the high and low pressure servicing connections.
  4. With a thermometer measure the air intake temperature, close to the outside air inlet at the plenum.
  5. With a thermometer measure the air outlet temperature, at the centre vent outlet.
  6. Run the engine at idle speed for 10 minutes or until normal operating temperature is reached.
  7. Read both pressure gauges and thermometers. Check readings against the guide-lines shown in the table below.
Ambient20°C25°C30°C35°C40°C
Outlet Temperature (°C)5 - 107 - 158 - 2011 - 2214 - 25
Low Pressure (bar)1.6 - 2.41.8 - 2.62.0 - 3.22.2 - 3.52.4 - 3.8
High Pressure (bar)14 - 1914 - 1914 - 2118 - 2319.6 - 24.8
NotesA + BA + BA + BBB

NOTES

  • The temperatures and pressures may be slightly increased for high humidity conditions.
  • The varying air conditioner pressure will dictate whether the fans operate in series or parallel, which will itself cause the temperatures and pressures to fluctuate. For example: A = Condenser and cooling fan both running at half speed (series) B = Condenser and cooling fan both running at full speed (parallel) A + B = Fans switching from series to parallel.