mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4927 > < Initial Inspection and Diagnostic Overview|Page 4925
Page 288
background image

1. Connect the special tool. Refer to "How to connect SWS monitor."  See: Scan Tool Testing and Procedures/How to Connect SWS Monitor
2. Operate scan tool MB991958 according to the procedure below to display "F.FOG."

a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f.

Select "LIGHTING."

g. Select "F.FOG."

3. Check that normal conditions are displayed for the items described in the table below.

Q: Does the scan tool MB991958 display the items "IG SW (IG1)" and "F.FOG LIGHT" as normal condition?

Normal conditions are displayed for all the items : Go to Step 3.

Normal condition is not displayed for "IG SW (IG1)" : Refer to INSPECTION PROCEDURE M-2 "ETACS-ECU does not receive any signal
from the ignition switch (IG1)."  See: Symptom Diagnostic Procedures/Inspection Procedure M-2

Normal condition is not displayed for "F.FOG LIGHT" : Refer to INSPECTION PROCEDURE M-3 "ETACS-ECU does not receive any
signal from the front fog light switch."  See: Symptom Diagnostic Procedures/Inspection Procedure M-3

STEP 3. Check front fog light relay connector A-07X for loose, corroded or damaged terminals, or terminals pushed back in the connector.