Page 75
background image

disconnecting scan tool MB991958.

1. Connect the special tool. Refer to "How to connect SWS monitor."  See: Scan Tool Testing and Procedures/How to Connect SWS Monitor
2. When the liftgate lock release switch is operated, check that scan tool MB991958 sounds.
3. Operate scan tool MB991958 according to the procedure below to display "Pulse check."

a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."

Q: Does scan tool MB991958 sound when the liftgate lock release switch is turned from "OFF" to "ON"?

YES : Go to Step 12.

NO : Refer to INSPECTION PROCEDURE N-6 "ETACS-ECU does not receive any signal from the liftgate lock release switch.  See: Symptom
Related Diagnostic Procedures/Symptom Diagnostic Procedures/Inspection Procedure N-6 <ECLIPSE>" 

STEP 12. Check liftgate lock actuator connector F-11 for loose, corroded or damaged terminals, or terminals pushed back in the connector.

Q: Is liftgate lock actuator connector F-11 in good condition?

YES : Go to Step 13.

NO : Repair or replace the damaged component(s). Refer to General (Electrical), Harness Connector Inspection. Verify that all the doors can be
locked and unlocked normally.

STEP 13. Check the liftgate lock actuator <ECLIPSE> or trunk lid latch switch <ECLIPSE SPYDER>.

Initial Inspection and Diagnostic Overview|Page 5179 > < Initial Inspection and Diagnostic Overview|Page 5177