mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2111 > < Initial Inspection and Diagnostic Overview|Page 2109
Page 47
background image

1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate the MUT-II according to the procedure below to display "ECU COMM CHECK."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHECK."

5. Scan tool MB991502 should show "OK" on the "ETACS ECU" menu.

Q: Is "OK" displayed on the "ETACS ECU" menu?

YES: Go to Step 2.

NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is impossible."

STEP 2. Check the input signal by using "FUNCTION DIAGNOSIS" of the SWS monitor.

Check the input signals from the following switches:

-

Ignition switch: OFF (key inserted)

-

Driver's door: open

-

Front passenger's door: closed

Operate the MUT-II according to the procedure below to display "KEY RMND. ALM."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "FUNCTION DIAGNOSIS"
5. Select "BUZZER."
6. Select "KEY RMND. ALM."