Check that normal conditions are displayed on the items described in the table.

NOTE:  The scan tool display changes when the driver's or the front passenger's door is opened. If any of the doors is open, the system can not be
checked correctly.

Q: Does the scan tool display the items "IG SW (IG1)", "FRONT DOOR SW" and "BUZZER" as normal condition?

YES: Replace the ETACS-ECU. The ignition key reminder tone alarm function should work normally.

NO:
-

The scan tool does not show the respective normal condition for item "IG SW (IG1)." Refer to Inspection Procedure O-2 "ETACS-ECU does not
receive a signal from the ignition switch (IG1)."

-

The scan tool does not show the respective normal condition for item "FRONT DOOR SW." Refer to Inspection Procedure O-6 "ETACS-ECU
does not receive a signal from the driver's or the front passenger's door switch."

-

The scan tool does not show the respective normal condition for item "BUZZER." Go to Step 3.

STEP 3. Check the input signal (by using the Pulse check).

Check the input signals from the key reminder switch.

-

Check whether scan tool MB991502 sounds or not when the ignition key is removed.

Operate the MUT-II according to the procedure below to display "PULSE CHECK."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."

Q: Does scan tool MB991502 sound when the ignition key is removed?

YES: Replace the ETACS-ECU.The ignition key reminder tone alarm function should work normally.

NO: Refer to Inspection Procedure P-1 "ETACS-ECU does not receive a signal from the key reminder switch."

Inspection Procedure B-2

Tone Alarm: Light Reminder Tone Alarm Function Does Not Work Normally.

NOTE:  This troubleshooting requires use of scan tool MB991502 and SWS monitor kit MB991862. For details of how to use the SWS monitor, refer
to "How to use SWS monitor."

Initial Inspection and Diagnostic Overview|Page 2112 > < Initial Inspection and Diagnostic Overview|Page 2110