background image

STEP 10. Check the wiring harness between power window relay connector C-224 (terminal 4) and power window sub-switch (front: RH)
connector E-14 (terminal 5)
.

NOTE:  Also check junction block connector C-211 and intermediate connector C-110 for loose, corroded, or damaged terminals, or terminals pushed
back in the connector. If junction block connector C-211 or intermediate connector C-110 are damaged, repair or replace the damaged component(s) as
described in Harness Connector Inspection.

Q: Is the wiring harness between power window relay connector C-224 (terminal 4) and power window sub-switch (front: RH) connector E-14 (terminal
6) in good condition?

YES: No action is necessary and testing is complete.

NO: The wiring harness may be damaged or the connector(s) may have loose, corroded or damaged terminals, or terminals pushed back in the
connector. Repair the wiring harness as necessary. When the power window sub-switch (front: RH) is operated, the front power window (RH) should
open or close normally.