mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2045 > < Initial Inspection and Diagnostic Overview|Page 2043
Page 371
background image

Inspection Procedure M-6

Column switch: ETACS-ECU does not receive any signal from windshield mist wiper switch, windshield intermittent wiper switch, windshield
low-speed wiper switch, windshield high-speed wiper switch, windshield washer switch
.

Windshield Wiper And Washer Switch Input Circuit

CIRCUIT OPERATION

The ETACS-ECU operates the following equipment or functions according to signal from the column switch (windshield wiper and washer switch):

-

Windshield wiper and washer

TECHNICAL DESCRIPTION (COMMENT)

If the signal is not normal, the equipment, which is described in "CIRCUIT OPERATION", does not work normally.

TROUBLESHOOTING HINTS

-

The column switch (windshield wiper and washer switch) may be defective

-

The ETACS-ECU may be defective

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: Vehicle Communication Interface (V.C.I.)

-

MB991827: MUT-III USB Cable

-

MB991911: MUT-III Main Harness B

-

MB991813: SWS Monitor Kit
-

MB991806: SWS Monitor Cartridge

-

MB991812: SWS Monitor Harness (For Column-ECU)

-

MB991922: Probe Harness

STEP 1. Use scan tool MB991958 to select "ECU COMM CHK" on the SWS monitor display.

Check the column-ECU.

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958. Connect the DLC harness before connecting the column-ECU harness. Be sure to connect SWS monitor kit

Initial Inspection and Diagnostic Overview|Page 2045 > < Initial Inspection and Diagnostic Overview|Page 2043