Montero XLS 4WD V6-3.5L SOHC (2001)
Seat Heater: Testing and Inspection
SEAT CUSHION HEATER CHECK
Measure the resistance between terminals.
Standard value: At room temperature 20 °C (68 °F)
Between terminals 2 and 3: Approximately 5.4 ohm ± 10%
Between terminals 1 and 3: 5.0 ohm ± 10%
SEATBACK HEATER CHECK
Measure the resistance between terminals.
Standard value: At room temperature 20 °C (68 °F)
Approximately 6.0 ohm ± 10%