mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Seat Heater Switch > < Diagram Information and Instructions|Page 6127
Page 1
background image

Seat Heater: Testing and Inspection

SEAT CUSHION HEATER CHECK

Measure the resistance between terminals.

Standard value: At room temperature 20 °C (68 °F)

Between terminals 2 and 3: Approximately 5.4 ohm ± 10%
Between terminals 1 and 3: 5.0 ohm ± 10%

SEATBACK HEATER CHECK

Measure the resistance between terminals.

Standard value: At room temperature 20 °C (68 °F)

Approximately 6.0 ohm ± 10%

Seat Heater Switch > < Diagram Information and Instructions|Page 6127