porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Testing Each One Separately|Page 1492 > < Testing Each One Separately|Page 1490
Page 2
background image

4. Remove vacuum hoses from the control boxes.

-

Push a small screwdriver between the connection nipple and vacuum hose.

-

Widen vacuum hose a little and spray in silicone spray at the same time.

-

Lever off or remove vacuum hose with angled pliers.

5. Connect vacuum hose of test device.

-

Connect angle pieces (shop made) and Tecalan lines (shop made) to the control boxes and connect with the pressure gauge.

-

Produce overpressure of 0.5 bar with special tool 9160/1.

-

Read off the pressure on the pressure gauge 9103/2.

-

Have a second person read off the stroke of the push rods at the same time.

-

The stroke of the push rod must amount to 4 ± 0.5 mm, adjust if necessary by rotating the adjusting nuts.

Turning clockwise - stroke smaller.
Turning anti-clockwise - stroke larger.

Testing Each One Separately|Page 1492 > < Testing Each One Separately|Page 1490