The observation window is activated once the fuel step is set and a defined time period has passed. This time period is defined by 0,8 multiplied with the
operating point dependent time delay plant parameter of the lambda control. The observation window is deactivated with the subsequent fuel step.

The quotient of measured and expected area is computed. For a nominal primary oxygen sensor the resulting dynamic value is close to 1. A lower result
value indicates a slow sensor (Figures 1-2).

To detect the fault cases, both slopes lean to rich and rich to lean are influenced.

The fault cases consist of transition-time faults (slow response of the lambda sensor signal gradient with respect to the gradient of the real lambda value)
and response-time faults (delayed response of the lambda sensor signal to lambda changes).

Overview of the fault cases:

A diagnostic result is calculated only if the number of individual measurements is greater than or equal to a calibrated threshold. If this happens the
diagnosis checks whether a direction-specific result shows a fault. Once this calibrated threshold is reached, the result value is evaluated.

Oxygen Sensor|Part 1|Page 1367 > < Oxygen Sensor|Part 1|Page 1365