porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Oxygen Sensor|Part 1|Page 1369 > < Oxygen Sensor|Part 1|Page 1367
Page 6
background image

The minimum value of,

-

Number of valid measurements (value of counter C(rl)) for a lean to rich step and number of valid measurements (value of counter C(lr)) for a rich
to lean step of the dynamic check in the current driving cycle, is equal to or exceeds a calibrated minimum.

This calibrated minimum is corresponding to the number of valid measurements, necessary for checking a malfunctioning system to compensate for
different time durations for passing and failing systems.

Conditions for incrementing the denominator

The denominator is incremented, if the monitor is not inhibited due to stored faults, when the general denominator conditions have been fulfilled for the
current driving cycle.

Flowcharts