01 Introduction02 General information03 Information04 Maintenance05 Engine - K806 Engine - K1607 Engine - K16 with VVC08 Engine - L Series09 Emission control10 Engine management system - MEMS11 Engine management system - EDC12 Fuel delivery system13 Cooling system - K Series14 Cooling system - L Series15 Manifold & exhaust systems16 Clutch17 Manual gearbox - R6518 Manual gearbox - PG119 Automatic gearbox - CVT20 Automatic gearbox21 Drive shafts22 Steering23 Front suspension24 Rear suspension25 Brakes26 Restraint systems27 Body28 Heating & ventilation29 Air conditioning30 Wipers & washers31 Electrical32 Instruments
Rover 200 Workshop Manual (1995-1999)29 · Air conditioning
29 · Heating & A/C

Air conditioning: Adjustments

Make
Rover
Model
200 Workshop Manual
Year
1995–1999
Section
Adjustments › Service precautions
Air conditioningService precautions

SERVICE PRECAUTIONS

Care should be taken when handling the components in the refrigeration system. Units must not be lifted by their hoses, pipes or capillary lines. Hoses and lines must not be subjected to any twist or stress. Ensure that hoses are positioned in their correct run before tightening couplings, and ensure that all clips and supports are used. Torque wrenches of the correct type must be used when tightening refrigerant connections to the stated value. An additional spanner must be used to hold the union to prevent twisting of the pipe.

Before connecting any hose or pipe ensure that refrigerant oil is applied to the seat of the new ’O’ ring seals but not to the threads.

Check the oil trap for the amount of oil lost.

All protective plugs must be left in place until immediately prior to connection.

The receiver/dryer contains desiccant which absorbs moisture. It must be positively sealed at all times.

CAUTION: Whenever the refrigerant system is opened, the receiver/dryer must be renewed immediately before evacuating and recharging the system.

Use alcohol and a clean cloth to clean dirty connections.

Ensure that all new parts fitted are marked for use with R134a.

Refrigerant oil

Use an approved refrigerant lubricating oil:

Sanden SP-10 Unipart SP-10

CAUTION: Do not use any other type of refrigerant oil.

Refrigerant oil easily absorbs water and must not be stored for long periods. Do not pour unused oil back into the container.

When renewing system components, add the following quantities of refrigerant oil:

Condenser 30cm33 Evaporator 30cm3 Pipe or hose 10cm3 Receiver dryer 30cm

Total amount of oil in the system: 135 cc

A new compressor is sealed and pressurised with Nitrogen gas, slowly release the sealing cap, gas pressure should be heard to release as the seal is broken.

NOTE: A new compressor should always have its sealing cap in place and must not be removed until immediately prior to fitting the compressor air conditioning pipes.

Rapid refrigerant discharge

If the air conditioning system is involved in accident damage and the circuit is punctured, the refrigerant will discharge rapidly. The rapid discharge of refrigerant will also result in the loss of most of the oil from the system. The compressor must be removed and all the remaining oil in the compressor drained and refilled as follows:

  1. Remove the drain plug and gravity drain all the oil, assisted by rotating the clutch plate(not the pulley).
  2. Refit the compressor with the following amount3 of new refrigerant oil: 100cm
  3. Refit the drain plug and plug the inlet and outlet port.

Parts & tools for this job For 1995 Rover 200