Workshop Manuals Factory service & repair Rover
01 Introduction02 General information03 Information04 Maintenance05 Engine - K Series06 Engine - D Series07 Engine - L Series08 Engine - T Series09 Emission control10 Engine management system - MEMS11 Engine management system - PGMFi12 Engine management system - EDC13 Fuel delivery system14 Cooling system15 Cooling system - L Series16 Manifold & exhaust systems17 Clutch18 Manual gearbox - R6519 Manual gearbox - PG120 Automatic gearbox21 Drive shafts22 Steering23 Suspension24 Brakes25 Restraint systems26 Body27 Heating & ventilation28 Air conditioning29 Wipers & washers30 Electrical31 Instruments
Rover 400 Workshop Manual (1995-2000)28 · Air conditioning
28 · Heating & A/C

Recovery and recycling (Air conditioning)

Make
Rover
Model
400 Workshop Manual
Year
1995–2000
Section
Adjustments › Recovery and recycling
Air conditioningRecovery and recycling

Recovery and recycling

  1. Connect a refrigerant station to high and low pressure servicing connections.
  2. Operate the refrigerant recovery system in accordance to the manufacturers instructions.

WARNING: Refrigerant must always be recycled before re-use, to ensure that the purity of the refrigerant is high enough for safe use in the air conditioning system.

Recycling should always be carried out with equipment which is design certified by Underwriter Laboratory Inc. for compliance with SAE - J1991. Other equipment may not recycle refrigerant to the required level of purity.

  • A R134a Refrigerant Recovery Recycling
  • Recharging Station must not be used with any
  • other type of refrigerant.
  • Refrigerant R134a from domestic and
  • commercial sources must not be used in motor
  • vehicle air conditioning systems.

Evacuation and recharging

  1. Add calculated refrigerant oil to the compressor as necessary.
  2. Renew receiver/drier.
  3. Connect a Refrigerant Station to the high and low pressure servicing connections.

CAUTION: Whenever the refrigerant system is opened, the receiver/drier must be renewed immediately before evacuating and recharging the system.

  1. Operate the refrigerant evacuation system according to the manufacturers instructions.

NOTE: If the vacuum reading is below 700 mm/Hg after 15 minutes, suspect a leak in the system. Partially recharge the system and check for leaks using an electronic leak tester.

CAUTION: The system must be evacuated immediately before recharging commences. Delay between evacuation and recharging is not permitted.

  1. Operate the refrigerant recharging system according to the manufacturers instructions.

Amount of refrigerant required to charge the system is: RHD = 560 gr ± 50 gr LHD = 640 gr ± 50 gr

  1. If the full charge has not been accepted by the system, start the engine and run it at 1500 rev/min.
  2. Switch on the air conditioning system, open the car windows, set the temperature control to cold and switch the blower to maximum speed.
  3. Consult the Refrigerant Station Manual for the correct procedure to complete the charge.
  4. Carry out the air conditioning system performance test See this section.

Parts & tools for this job For 1995 Rover 400

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.