01 Introduction02 General information03 Information04 Maintenance05 Engine - K Series06 Engine - D Series07 Engine - L Series08 Engine - T Series09 Emission control10 Engine management system - MEMS11 Engine management system - PGMFi12 Engine management system - EDC13 Fuel delivery system14 Cooling system15 Cooling system - L Series16 Manifold & exhaust systems17 Clutch18 Manual gearbox - R6519 Manual gearbox - PG120 Automatic gearbox21 Drive shafts22 Steering23 Suspension24 Brakes25 Restraint systems26 Body27 Heating & ventilation28 Air conditioning29 Wipers & washers30 Electrical31 Instruments
Rover 400 Workshop Manual (1995-2000)28 · Air conditioning
28 · Heating & A/C

Refrigerant recovery, recycling and recharging (Air conditioning)

Make
Rover
Model
400 Workshop Manual
Year
1995–2000
Section
Adjustments › Refrigerant recovery, recycling and recharging
Air conditioningRefrigerant recovery, recycling and recharging

REFRIGERANT RECOVERY, RECYCLING AND RECHARGING

Refrigerant recovery, recycling and recharging

Service connections

  1. High pressure service connection
  2. Low pressure service connection

NOTE: An air conditioning portable Refrigerant Recovery, Recycling and Recharging Station for use with R134a refrigerant incorporates all the features necessary to recover refrigerant R134a from the A/C system, to filter and remove moisture, to evacuate and recharge with reclaimed refrigerant. The unit can also be used for performance testing and air conditioning system analysis.

Parts & tools for this job For 1995 Rover 400