Renew
- Make
- Rover
- Model
- Coupé, Cabriolet & Tourer 200/400 Coupé, Cabriolet & Tourer Workshop Manual
- Section
- Fault finding › Renew
FAULT: Airbag SRS warning light constantly illuminated when starter switch is turned to position 'II'.
ALWAYS follow the following precautions before fault finding on the SRS system:
- Remove key from starter switch and disconnect both battery leads, earth lead first.
- Wait 10 minutes to allow the SRS back-up circuit to fully discharge.
- Carry out the full fault finding procedure before powering up the system.
Renew
- Renew the airbag control unit, see Airbag control unit.
CAUTION: The airbag control unit is a non-serviceable component and no attempt to repair or modify the module should be made.
System Check
- Reassemble the complete SRS system in the reverse order of removal. Ensure new Torx screws are used and all screwed components are tightened to their specified torque.
WARNING: Failure to tighten the airbag control unit to steering wheel Torx screws to their correct torque will severely affect the performance of the SRS system.
- Ensure all connectors are fully connected.
- Connect both battery leads, earth lead last.
- Insert key into starter switch and turn to position 'II'. The SRS warning light should illuminate for approximately 3 seconds then extinguish.
- If the SRS warning light stays illuminated renew the drivers airbag module, see Drivers airbag module.
- Repeat system check.