8. CONNECT SUCTION HOSE SUB-ASSEMBLY

a. Remove the vinyl tape attached to the hose and condenser.

1. Lubricate 2 new O-rings with compressor oil and install them to the hose.

Compressor oil: ND-OIL 8 or equivalent

b. Connect the suction hose and piping clamp.

1. Connect the bracket with the bolt.

Torque: 9.8 N.m (100 kgf.cm, 7 ft.lbf)

9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

10. PERFORM INITIALIZATION

a. Perform initialization.

NOTE:  Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.

11. CHECK SRS WARNING LIGHT

a. Check the SRS warning light.

12. CHARGE REFRIGERANT
13. WARM UP ENGINE
14. CHECK FOR LEAKAGE OF REFRIGERANT