Check:
Warning
Danger of fuel escaping.
Fuel system is under pressure.
Before opening the system place a cloth around the connection. Then release pressure by carefully loosening the connection.
Disconnect fuel line at metering pump V54 and seal using suitable means.
Connect the 300 mm long fuel hose to the metering pump V54.

Hold measuring glass at same height as auxiliary heater.
Using vehicle diagnosis, testing and information system VAS 505X, open guided function „Check quantity of fuel delivered“ (open fuel line for metering pump V54) and start.
After approx. 30 seconds, the fuel line is filled and bled.
Seal fuel line.
Empty measuring glass.

Hold measuring glass at same height as auxiliary heater.
Using vehicle diagnosis, testing and information system VAS 505X, open guided function „Check quantity of fuel delivered“ (open fuel line for metering pump V54) and start.
Fuel supply finishes after approx. 120 seconds.
Connect connector to fuel line.
Read measuring glass. Fuel delivery rate for petrol and diesel: 22 to 28 ml.
If fuel delivery rate is not within specifications, renew metering pump V54.