Deactivation
- Make
- SEAT
- Model
- Alhambra
- Year
- 2010–2020
- Section
- Supplementary heating › Deactivation
Deactivation
When switched off manually or after a maximum operating time of 60 minutes or the coolant reaches a temperature of 84° C, combustion is ended and the run-on mode begins. The circulation pump V55 and the combustion air blower V6, however, continue to run to cool down the auxiliary heater (run-on mode) and are switched off automatically.
Note
- recirculating pump V55 and the combustion air blower V6 depend on the operating mode in which the auxiliary heater was switched off.
The post-operation period is 175 seconds when heater is switched off during full-load and 110 seconds for part-load.
Depending on the control unit software version, slight deviations in the specified run-on values are possible.