01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Altea / Altea XL / Freetrack (2004-2015)44 · Air conditioner
44 · Heating & A/C

Safety precautions

Make
SEAT
Model
Altea / Altea XL / Freetrack
Year
2004–2015
Section
Heating and air conditioning › Safety precautions
Air conditionerSafety precautions

Safety precautions

Heating, ventilation, air conditioning system · Heating and air conditioning · Safety precautions for work on vehicles with air conditioning and how to work with refrigerant R134a · Altea, Toledo from 2005 · Edition 12.2010

The following safety measures are to be followed for this refrigerant (additional regulations may apply in other countries).

If work is required on the refrigerant circuit then this circuit must first be emptied Chapter “Safety precautions”. Any contact with the refrigerant liquid or vapours of this liquid must be avoided. Should any of the refrigerant be spilled despite precautions then the mix of air and refrigerant must not be breathed in.

In this situation, turn on any suction system and protect hands with gloves and the eyes with protective glasses.

Reasons:

The intensive action of the refrigerant on unprotected parts of the body may lead to freezing of those parts.

Warning

It is recommended that you always have an eye-bath ready for use in case it is needed.

If the refrigerant comes into contact with the eyes, immediately begin thorough rinsing of the eyes for 15 minutes.

Then, apply eye drops and seek medical assistance even if the eyes do not cause any pain.

The medical assistance must be given all of the details of the refrigerant causing the problem.

If, despite taking the safety precautions, any part of the body comes into contact with the refrigerant, also rinse thoroughly and immediately with cold water for about 15 minutes minimum.

Even though the refrigerant is not flammable, in any enclosed space where work is carried out with the refrigerant, smoking and electric welding equipment as well as hard or soft soldering work are forbidden.

Reasons:

If the refrigerant comes into contact with flame or hot elements, the gas in the refrigerant is chemically separated. When this released poisonous gas is breathed in, it produces an irritated cough and dizziness.