01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Altea / Altea XL / Freetrack (2004-2015)44 · Air conditioner
44 · Heating & A/C

Working on the refrigerant circuit

Make
SEAT
Model
Altea / Altea XL / Freetrack
Year
2004–2015
Section
Heating and air conditioning › Working on the refrigerant circuit
Air conditionerWorking on the refrigerant circuit

Working on the refrigerant circuit

Heating, ventilation, air conditioning system · Heating and air conditioning · Safety precautions for work on vehicles with air conditioning and how to work with refrigerant R134a · Toledo from 2005 · Edition 07.2007

Work on the refrigerant circuit should only be carried out in well ventilated areas. At the same time, ensure absolutely that within a radius of 5 meters there are no mechanic pits, wells or cellar entrances. Turn on all ventilation equipment.

Reason

The refrigeration agent that leaks into the air is colourless, odourless and is also more dense than air and thus displaces the oxygen. If, despite taking the necessary precautions, there is a leak of refrigerant, there is a danger of asphyxia without any warning, especially in insufficiently ventilated areas or in mechanics pits.

Note

  • The mixture of gas and air which forms when refrigerant gas escapes must not be inhaled. Use must be made of suitable workshop extractors.

Never carry out any welding work of any kind on or near the air conditioning system if it still contains refrigerant. The same applies to all vehicles if there is a risk of heating elements of the air conditioning system.

Reason

Due to heating, there will be an extreme pressure build up in the air conditioning installation which could lead to an explosion of the system.

Remedy

Drain the refrigerant circuit Chapter “Safety precautions”.

Note

  • No damaged or non-airtight part of the air conditioning may be repaired using welding and they must be replaced by new parts.

When servicing air conditioner, all open components and pipe connections are to be immediately re-sealed.

Reason

Moisture will penetrate the air conditioner component if they are left open for a long period. If this is the case, air conditioners cannot be re-filled without having to replace parts of the system.