seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Manually regulated air conditioning: repairing > < Capacities
Oil distribution
Oil distribution
In the refrigerant circuit the oil in the oil compressor tray is distributed, before the first start of air conditioning. The distribution in the refrigerating circuit with an evaporator is:
   
t  Compressor
50% approx.
t  Condenser
10% approx.
t  Intake flexible hose
10% approx.
t  Evaporator
20% approx.
t  Drier liquid tank
10% approx.

  Note!
Due to its chemical properties, the refrigerant circuit oil should not be eliminated together with the engine oil or lubricating oils.
   

Manually regulated air conditioning: repairing > < Capacities