seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Capacity > < Refrigeration performance of the air conditioning: check|Testing
Locating faults in case of an increase in temperature after the evaporator
   
Locating faults in case of an increase in temperature after the evaporator
–  Pinch off both coolant tubes to heating system heat exchanger e.g. using the clamp -U-30042-.
–  Repeat cooling performance test → Chapter.
l  Do the measurement values in the two display fields for the Servomotor for the left-hand side temperature flap (01809) -V158-, Servomotor for the right-hand side temperature flap (01810) -V159- (Climatic: Servomotor for the temperature flap (01271-4122) -V68-) only differ by less than 3°C from the measurement value of the Air temperature sender, evaporator output (00818) -G263-? → Vehicle diagnosis, testing and information system VAS 5051

yes


no

–  Remove the pressure clip -U-30042-.
–  Check correct installation of sender with measured value deviation, as well as checking electrical connections for contact resistance.
–  Check the activation and operation of the Servomotor for the left-hand side temperature flap (01809) -V158-, Servomotor for the right-hand side temperature flap (01810) -V159- (Climatic: Servomotor for the temperature flap (01271-4122) -V68- → Chapter and → Chapter.

Continued on the following page
–  Eliminate the cause of the faulty measurement, replace the faulty sender.

   
l  Are the activation and operation of the Servomotor for the left-hand side temperature flap (01809) -V158-, Servomotor for the right-hand side temperature flap (01810) -V159- (Climatic: Servomotor for the temperature flap (01271-4122) -V68- correct?

yes


no

–  Check the operation of the temperature flap from the side of the air distribution where there is a rise in temperature → Chapter.
–  If necessary, replace the air distribution housing → Chapter.
–  Repeat cooling performance test → Chapter.
–  Eliminate the cause of malfunction → Vehicle diagnosis, testing and information system VAS 5051 → Current flow diagrams, Electrical fault finding and Fitting locations
 
–  Repeat cooling performance test → Chapter.

   

Capacity > < Refrigeration performance of the air conditioning: check|Testing